Produktdetaljer
Produkttaggar
BY1-12,5/1P+1 | | | 75 | 150 | 275 | 320 |
IEC Elektrisk | |
Nominell AC-spänning (50/60 Hz) | | | 60v | 120v | 230v | 230v |
Maximal kontinuerlig driftspänning | (LN) | Uc | 75V | 150v | 275v | 320v |
(N-PE) | Uc | 255V | 255v | 255v | 255v |
Nominell urladdningsström (8/20μs) | (LN)/(N-PE) | In | 20KA/25KA |
Maximal urladdningsström (8/20μs) | (LN)(N-PE) | lmax | 50KA/50KA |
Impulsurladdningsström (10/350 μs) | (LN)/(N-PE) | limp | 12,5KA/25KA |
Specifik energi | (LN)/(N-PE) | W/R | 39KJ/Ω /156KJ/Ω |
Avgift | (LN)/(N-PE) | Q | 6,25As/12,5As |
Spänningsskyddsnivå | (LN)/(N-PE) | Up | 700v/1500v | 1000v/1500v | 1500v/1500v | 1600v/1500v |
Följ aktuell avbrottsklassificering | (N-PE) | Ifi | 100 ARMAR |
Svarstid | (LN)/(N-PE) | tA | <25ns/<100ns |
Reservsäkring (max) | | | 315A/250AgG |
Kortslutningsströmvärde (AC) | (LN) | ISCCR | 25KA/50KA |
TOV Tål 5s | (LN) | UT | 114V | 180V | 335V | 335V |
TOV 120 min | (LN) | UT | 114V | 230V | 440V | 440V |
Läge | | Motstå | Säkert misslyckande | Säkert misslyckande | Säkert misslyckande |
TOV Tål 200ms | (N-PE) | UT | 1200v |
Antal portar | | | 1 |
UL elektrisk | |
Maximal kontinuerlig driftspänning (AC) | (LN)/(N-PE) | MCOV | 75v/255v | 150v/255v | 275v/255v | 320v/255v |
Spänningsskyddsklassning | (LN)/(N-PE) | VPR | 330v/1200v | 600v/1200v | 900v/1200v | 1200v/1200v |
Nominell urladdningsström (8/20μs) | (LN)/-PE) | In | 20kA/20KA | 20kA/20KA | 20kA/20KA | 20kA/20KA |
Kortslutningsströmvärde (AC) | (LN) | SCCR | 100 KA | 200KA | 150KA | 150KA |
Tidigare: BY1-12,5 1P 2P 3P 4P Nästa: BY1-12,5-PV